We will call you back soon!
Physical Dimensions
Component | Material | Standard Shield | Tri-Shield | Quad-Shield |
Center Conductor | CCS / BC | 1.02 mm | 1.02 mm | 1.02 mm |
Dielectric | Gas Foam PE | 4.57 mm | 4.57 mm | 4.57 mm |
First Shield | Bonded AL Foil | 100% | 100% | 100% |
Second Shield | AL Wire | 60%/64/0.16 mm | 60%/64/0.16 mm | 60%/64/0.16 mm |
Third Shield | AL Foil | ☆ | 100% | 100% |
Fourth Shield | AL Wire | ☆ | ☆ | 40%/48/0.16 |
Jelly | Jelly | ※ | ※ | ※ |
Jacket | PVC/PE | 6.91 mm | 7.06 mm | 7.54 mm |
Mechanical Characteristics
Operating Temperature Range:---------------20℃ To +75℃
Max. Recommended Pulling Tension: -----21 kgs
Min. Bend Radius (Install):-------------------76 mm
Electrical Characteristics
Sparker Test:----------------4000VAC
Impedance:------------------75+3Ω
Capacitance:-----------------54+3pF/m
Velocity of Propagation:---85%
SRL:--------------------------20dB (5-1000MHz) / 15dB (1001-3000MHz)
Attenuation
Nominal Impedance(Ohm) | 75±3 | ||
Nominal Velocity Of Propagation(%) | 85 | ||
Nominal Capacitance(Pf/m) | 50 | ||
Sparker Test(Vac) | 3000 | ||
Srl(Db) | 20 | 20 | |
Attenuation | Frequency(Mhz) | Maximum(Db/100ft) | Maximum(Db/100m) |
5 | 0.58 | 1.9 | |
55 | 1.6 | 5.25 | |
187 | 2.85 | 9.35 | |
300 | 3.55 | 11.64 | |
450 | 4.4 | 14.43 | |
600 | 5.1 | 16.73 | |
750 | 5.65 | 18.54 | |
865 | 6.1 | 20.01 | |
1000 | 6.55 | 21.49 | |